92027 LCMS TDM Series A 3PLUS1 calibrator antidepressants2_psychostimulants

3PLUS1® Multilevel Plasma Calibrator Set Antidepressants 2/ Psychostimulants

Order no.: 92027
  • Atomoxetine
  • Methylphenidate
  • Mianserin
  • Reboxetine
  • Ritalinic acid
  • Trazodone
Component of the Parameter Set Antidepressants 2 / Psychostimulants, available separately

Description

3PLUS1® Multilevel Plasma Calibrator Set for the Parameter Set Antidepressants 2/Psychostimulants, lyophilised.

These lyophilised calibrators from Chromsystems are based on human plasma and should be used according to the instruction manual. They are designed to calibrate the measurement method in clinical diagnostics for the quantitative determination of antidepressants 2 and psychostimulants in serum/plasma. While following the instructions the calibrators should be handled and measured in the same manner as a patient specimen.
These calibrators are only available as multilevel calibrator set with 3 different concentration levels plus 1 blank value.

Technical Data

Method of Analysis

LC-MS/MS

Content

4 x 1 ml (lyoph.)

Parameter

Atomoxetine, Methylphenidate, Mianserin, Reboxetine, Ritalinic acid, Trazodone

Concentrations

Please note: Concentration values shown here are typical. For lot specific concentration values please refer to the product insert supplied with the materials. The product inserts can also be requested from us directly or downloaded from our website after login.

Substance Calibrator 1
(µg/l)
Calibrator 2
(µg/l)
Calibrator 3
(µg/l)
Blank Calibrator
(µg/l)
Atomoxetine  22.9  629  1208 n.d. (< 3.5)
Methylphenidate  3.03  38.1  73.2 n.d. (< 1.5)
Mianserin  7.09  93.8  184 n.d. (< 2.0)
Reboxetine  19.3  198  379 n.d. (< 1.0)
Ritalinic Acid  29.6  199  371 n.d. (< 3.5)
Trazodone  255  1665  2902 n.d. (< 4.0)

n.d. = not detected (< LOQ)
The blank level is manufactured using the same matrix pool as used for the calibrator levels 1, 2 and 3. It was not fortified with any drugs.

Reconstitution

Carefully remove the metal seal and rubber stopper from the vials. Add exactly 1.0 ml of distilled water into each vial. Return the stopper and incubate for 10 to 15 minutes at room temperature. Swirl the vials to dissolve the contents until homogeneity.

Storage conditions

Stored below -18 °C and unopened, the lyophilised calibrators are stable until the expiry date specified on the vial labels. The reconstituted calibrators can be stored in glass containers up to 24 hours light protected and tightly capped at +2 to +8 C. If the calibrators cannot be used within this period, they should be aliquoted and stored frozen below -18 °C (up to 3 months). For more details about storage conditions please check your instruction manual.